4. Push cable through gland opening.
Figure4-15 Connection - SSL cable inside
5. Connect the four wires according to list below.
Terminal number Description Wire color (SSL cable)
17 Vcc+ Orange
18 Vcc- Yellow
19 Rx White
20 Tx Blue
6. Assemble and tighten cable gland.
Connecting sensor DSL
1. Remove lock screw and remove DSL lid.
2. Undo the exible strap.
3. Disconnect sensor connection from DSL cassette.
4. Loosen mounting screw using a TX10 Torx driver and remove DSL cassette from housing.
5. Remove cap and ferrule from cable gland and slide onto cable.
6. Push cable through open gland; anchor cable screen and wires with clamp bar.
7. Remove terminal block from DSL cassette.
Connecting
4.7Connecting wall mount enclosure
SITRANS FS130 & FS230
Compact Operating Instructions, 12/2023, A5E38755607-AF 71