Connecting
5.4 Sensor wiring
FSS200 clamp-on sensors
Installation Manual, 08/2017, A5E36255466-AC
53
Triaxial cable and F-connector assembly
Assemble the cable and F-connector as follows:
1. Push and twist the F-connector
⑨ on the cable until secure.
2. Ensure the dielectric
⑦ is flush to 1mm (.04 in) beyond barrel end and that the center
conductor
⑧ is 1.5mm (0.06 in) beyond the F-connector body ⑨.
Connecting triaxial cables
Sensor grounding wire clamp components
Note
Triaxial cables are optionally available for the FST030 only.
The triaxial sensor cable must have a grounding connection from the cable gland to earth
ground. The cable is shipped with the grounding clamp parts and instructions sealed in a
separate plastic bag.