Technical data
7.3 Triaxial cable specifications
FSS200 clamp-on sensors
Installation Manual, 08/2017, A5E36255466-AC
83
High Temperature triaxial cable
Cable (75 Ω)
Triaxial cable terminated on both ends with F connectors
Outside diameter Ø 7.0 mm (0.276")
Length
5, 20m (16.40, 65.62 ft) between sensor and transmitter.
Material (outside jacket)
Yellow FEP Perfluorethylenpropylen jacket
Ambient temperature
-55 - +204°C (-67 - +400°F)