Additional Installation Instructions
B.2 Mounting tracks for Size A and B sensors
FSS200 clamp-on sensors
94 Installation Manual, 08/2017, A5E36255466-AC
B.2
Mounting tracks for Size A and B sensors
Using sensor mounting tracks
The FSS200 Universal and Hi Precision mounting tracks provide a rigid mounting platform
for Series 1011 Universal or Hi Precision size A or B sensors. The mounting tracks service
pipe sizes up to a maximum of 140 mm (5.00") outer diameter. The mounting tracks support
both Direct and Reflect mounting modes. The transmitter recommends the appropriate
sensors, mounting track and mounting mode, based on the pipe data entries.
Installing a mounting track in Reflect mode
1.
Use the Wizard setup procedure to program the transmitter for the sensors that were
selected.
2. After receiving the spacing number index from the transmitter, make a note of the number
displayed.
3. Prepare the pipe surface. De-grease the surface, if necessary, and remove any grit,
corrosion, rust, loose paint, etc. Use abrasive material provided to provide a clean contact