EasyManua.ls Logo

Siemens SITRANS FST030 - Page 225

Siemens SITRANS FST030
356 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Modbus
register
Data type /
Size in bytes
Parameter Description Default value
[units]
(units register)
Value range /
Setting options
Access
level
9204 Unsigned / 2 Process value Select process value
for the current output.
0
0: Mass flow
1: Volume flow
2: Density
3: Medium
temperature
18: Sound velocity
19: Flow velocity
20: Pressure
21: Viscosity
22: RTD temperature
1
23: RTD temperature
2
24: Medium
concentration
25: Measured current
(Channel 5)
26: Measured current
(Channel 6)
27: Standard volume
flow rate (only
hydrocarbon and gas
applications)
28: Standardizing
factor (only
Read /
write
Modbus communication
A.9 Modbus holding registers tables
SITRANS FST030 (Modbus)
Operating Instructions, 08/2018, A5E37367739-AD 225

Table of Contents

Related product manuals