Pipe settings
Sensor settings (2)
Pipe class
Sensor settings
Pipe size
Outer diameter + wall thickness
Circumference + wall thickness
Outer pipe diameter
Wall thickness
Custom
Custom

Liner
Wall sound velocity
Yes
No
Liner material
Liner settings
Yes
No
Pipe circumference
Inner pipe roughness
1)
Select material
Pipe expansion
1)
Disturbed flow
Text Options/Description
Pipe settings Select "Yes" to configure the pipe.
Pipe class Select the pipe class.
Pipe size Select the pips size from the options available for the selected pipe class.
Pipe circumference Enter pipe circumference. Only available if custom pipe class is selected.
Outer pipe diameter Enter outer pipe diameter. Only available if custom pipe class is selected.
Wall thickness Enter wall thickness. Only available if custom pipe class is selected.
Select material Select the pipe material.
Wall sound velocity Enter the wall sound velocity of the material. Only available if custom
material is selected.
Commissioning
6.6 Commissioning via local display
SITRANS FST030 (Modbus)
Operating Instructions, 08/2018, A5E37367739-AD 57