Inputs/Outputs wizard
The Inputs and outputs wizard will guide you through setup of inputs and outputs on the
available channels. The availability of channels 3 and 4 depends on the product configuration.
Inputs/Outputs wizard
First you must set the output functionality you want the channel to operate. Choose between
Off, Current output, Frequency output, Pulse output, or Status output, Digital input or Current
input.
Channel 2 provides output functionality only.
Channel 3 and 4 provide input or output functionality.
If one of the channels 3 or 4 is configured to relay the functionality of this channel is reduced to
Status output.
Inputs/Outputs
Start
Quick start
Quick commissioning
Sensor settings
Process values
Inputs and outputs
Copy configuration
CH3 operating mode
Off
Current output
Frequency output
Pulse output
Status output
Digital input
Current input
Channel 2 - output
Channel 3 - input/output
Channel 4 - input/output
Next
Select channel
Finished
Current output - channels 2 to 4
Current output - channels 2 to 4
The Current output can be configured to 0...20 mA or 4...20 mA. You can assign a process
value to the current, set the direction, the damping value, the lower range value, the upper
range value, and the fail-safe behaviour.
Commissioning
6.6 Commissioning via local display
SITRANS FST030 (Modbus)
Operating Instructions, 08/2018, A5E37367739-AD 63