Sensor system nameplate
SITRANS FUE380
Sensor:
Serial No.:
Dimension:
Process Con.:
qs:
qp / qi:
Θmin to Θmax:
Cal. Factor:
T-amb.:
MAWP (PS) at ...
°C (TS):
MAWP (PS) at ...
°C (TS):
Fluid group:
xxxx....
xxxx....
DN...
xxxx....
...m3/h
.../... m3/h
+15 °C to +200°C
xxxx....
-10 to +55 °C
....bar
....bar
.../...
SYSTEM No.
Serial No.:
Year of Manuf.:
Meter orientation:
xxxx....
xxxx....
2018
Horizontal
0200
M18
Siemens AG, DE-76181 Karlsruhe
Made in France
Accuracy Class: 2
Certification No.: DK-0200-MI004-005
Environmental Class: E2, M1
① Manufacturer
② Product type
③ Sensor number and serial number
④ Dimension (nominal size ordered)
⑤ Process connections
⑥ Maximum flow value (qs), Nominal flow value (qp), Minimum flow value (qi)
⑦ Water temperature range
⑧ Calibration factor
⑨ Ambient temperature range
⑩ Maximum allowable working pressures at 15 °C (59 °F) and 200°C (392 °F) (max. tempera‐
ture (TS))
⑪ Fluid group
⑫ System number and system serial number
⑬ Year of manufacture
⑭ Meter orientation
⑮ Type approval number (shown on FUE380 versions only)
⑯ Accuracy class (shown on FUE380 versions only)
⑰ Environmental class (shown on FUE380 versions only)
⑱ Conformity with country-specific directives
⑲ Verification and PED markings (verification marking shown on MID-verified FUE380 versions
only)
Figure 1-2 Sensor system nameplate, FUE380 example
Note
The matched paired transmitter and sensor shall be mounted together
At installation, please check that the system nameplates of transmitter and sensor have the
same system serial number.
Introduction
1.4 Device identification
SITRANS FUS380/FUE380