Note
Optional current output module
If you want to install the optional current output module, proceed with chapter Installing and
connecting optional current output module (Page 44) before mounting the transmitter.
5.4.2.5 Finishing connection
Mount the transmitter.
Note
Grounding
To ensure identical potential for sensor and transmitter, a direct grounding of transmitter and
sensor is recommended.
Note
Aligning the gasket
Please ensure that the gasket between terminal box and transmitter is well aligned before
tightening the screw (Min. torque 0.5 Nm).
Note
Remote connection cable
If the Siemens sensor link cable is shortened, the factory set "Cable length" setting must be
corrected.
This setting can only be changed if the HW key is mounted, which requires demounting of the
transmitter. In case the FUE380 is protected by a physical verification sealing, this must be
broken which may only be done with the acceptance of the authorities.
5.5 Optional current output module
The optional current output module converts the flow signal into a 4-20 mA output signal. The
4 mA always equals 0 flow rate and the 20 mA equals the Qp value selected via the order code.
The default Qp can be found on the transmitter nameplate.
Connecting
5.5 Optional current output module
SITRANS FUS380/FUE380
Operating Instructions, 05/2018, A5E00730100-AE 43