INSTALLATION 3
37
SITRANS FX330
www.siemens.com/flow08/2022 - A5E36751269-AG EN
3.8.3 Installing devices in flange design
Use bolts and fastening nuts to attach the measuring device to one side of the flange.
While doing so,
insert the gaskets between flow sensor and flange and align them.
Check that the gasket is concentric and that it is not protruding into the pipe cross-section.
Install the gasket, bolts and fastening nuts on the other side of the flange.
Align the measuring device and the gaskets so they are concentric.
Now tighten all nuts bit by bit alternately across the diagonal.
Figure 3-15: Installing devices in flange design
1 Sealing
2
Bolts with fastening nuts

Table of Contents