Technical data and dimensions
13
13.1 Technical data
Note for approved transmitters
Device specifications:
Siemens makes every effort to ensure the accuracy of these specifications, but
reserves the right to change them at any time.
Device-specific approvals:
The device-specific approvals are always to be found on the type plates on the
device.
Materials and weights
Materials, wetted parts
Antenna PVDF
Counter nut
a
PP
Materials, non-wetted parts
Housing PVDF
Cable entry seal NBR
Connection cable PVC
Weight
Transmitter 0.7kg (1.543lbs)
Connection cable 0.1kg/m
Mounting connection Thread G1, R1, 1NPT
a
G type threaded connections only
Input variable
Measured variable The measured variable is the distance between the antenna edge of
the transmitter and the medium surface. The antenna edge is also
the reference point for the measurement.
Measuring range
a
0…30m (0…98.43ft)
blocking distance
b
Frequencies 1, 2, 4 0mm (0in)
Frequency 3 ≥250mm (9.843in)
a
Depending on application and medium
SITRANS LR120
Operating Instructions, 08/2020, A5E49829026