Technical data and dimensions
12
12.1 Technical data
Note for approved transmitters
Device specifications: Siemens makes every effort to ensure the accuracy of these
specifications, but reserves the right to change them at any time.
Device-specific approvals: The device-specific approvals are always to be found on
the nameplates on the device.
Materials and weights
Materials, wetted parts
Antenna, process fitting PVDF
Counter nut
a
PP
Process seal FKMG type threaded connections only
Materials, non-wetted parts
Housing PVDF
Cable entry seal NBR
Connection cable PVC
Weight
Instrument 0.7kg (1.543lbs)
Connection cable 0.1kg/m
Process fitting Thread G1½, R1½, 1½NPT
Mounting connection Thread G1, R1, 1NPT
Max. torque mounting boss 7Nm (5.163lbf ft)
a
G type threaded connections only
Input variable
Measured variable The measured variable is the distance between
the antenna edge of the transmitter and the
medium surface. The antenna edge is also the
reference point for the measurement.
Max. measuring range
a
8m (26.25ft)
Minimum measuring distance
b
Mode 1, 2, 4 0mm (0in)
SITRANS LR100