7ML19985JF02 SITRANS LR250 (PROFIBUS PA) – INSTRUCTION MANUAL Page 7
mmmmm
Specifications
Environmental
• location indoor/ outdoor
• altitude 5000 m (16,404 ft) max.
• ambient temperature −40 to +80 °C (−40 to +176 °F)
• relative humidity suitable for outdoor
Type 4X/NEMA 4X, Type 6/NEMA 6, IP67, IP68 enclosure
(see note below)
• installation category I
• pollution degree 4
Process
•temperature
1)
−40 to +200 °C (−40 to +392 °F)
(at process connection
with FKM O-ring)
• pressure (vessel)
1)
Refer to
Process Pressure/Temperature derating curves
on
page 120.
Approvals
•General CSA
US/C
, FM, CE
• Radio Europe ETSI EN302-372, FCC, Industry Canada
• Hazardous Intrinsically Safe
2)
(Europe) ATEX II 1G, EEx ia IIC T4
ATEX II 1D, EEx tD A20 IP67 T90 °C
(International) IECEx SIR 05.0031X,
Ex ia IIC T4,
EX tD A20 IP67 T90 °C
(continued on next page)
Notes:
• Check
Approvals
on page 7, for the specific configuration you are about to use or
install.
• Use appropriate conduit seals to maintain IP or NEMA rating.
1)
The specifications apply to the standard configuration only (with FKM O-ring).
Maximum and minimum temperatures are dependent on the process connec-
tion, antenna and O-ring materials, and vessel pressure. For more detail, or for
other configurations, see
Maximum Process Temperature Chart
on page 119,
and
Process Pressure/Temperature derating curves
on page 120.
Note: The device nameplate lists the approvals that apply to your device.
2)
See
Intrinsically Safe wiring
on page 20