Page 48 SITRANS LR250 (PROFIBUS PA) – INSTRUCTION MANUAL 7ML19985JF02
mmmmm
SIMATIC PDM
To perform a reset to Factory Defaults:
1) Open the menu Device – Device Reset, and click on Factory Defaults.
2) After the reset is complete click on Close, then upload parameters to the PC/PG.
(If you are performing a reset after replacing the device with a different
instrument, do not upload parameters to the PC/PG.)
Write Locking
If Write Locking is enabled, the data can be viewed but not modified. See
Write Locking (6.1.)
on page 98 for more details.
To enable/disable Write Locking:
1) Open the menu Device – Write Locking and select On or Off.
2) Click on Transfer.
Display
To compare outputs in real time open the menu View Display.