9.2.5.2 Vessel dimension A (2.5.2)
Sets height of vessel bottom when bottom is conical, parabolic, half spherical, or 󹪞at sloped. If
horizontal parabolic ends vessel, sets depth of end.
Setting 0 to 99.999 m
Default 0
See Vessel shape (2.5.1) (Page123) for illustration.
9.2.5.3
Vessel dimension L (2.5.3)
Sets length of cylindrical section of horizontal parabolic ends vessel.
Setting 0 to 99.999 m
Default 0
See Vessel shape (2.5.1) (Page123) for illustration.
9.2.5.4
Volume units (2.5.4)
Sets volume measurement units.
Setting
Cubic meters m
3
Hectoliters hl
Cubic inches in
3
Cubic feet ft
3
Bushels bu
Cubic yards yd
3
42 US gallon barrels bbl
31.5 US gallon barrels bbl (US)
Normal liters Nl
Normal cubic meters Nm
3
Standard cubic feet SCF
Default Cubic meters m
3
9.2.5.5 Upper scaling point (2.5.5)
Se
ts maximum scaled measurement value.
Setting 0 to 9999.999 m
3
Default 1000.0 m
3