Installing and Mounting
4.2 Mounting instructions
SITRANS LUT400
Operating Instructions, 07/2019, A5E33329501-AC
25
4.2.1.2 Mounting the remote lid
Note
Remote mounted lid can be mounted up to 5 m from the device using two optional cable
extensions (each 2.5 m in length). For instructions on how to connect an extension cable,
see
Remote mounted lid with extension cable (Page 46).
1. Using the template provided, cut out the necessary hole for the remote LUI display lid.
Place the gasket inside the lid, aligning the mounting holes. Align the back of the remote
display lid with the panel hole cut-out. Mark and drill four holes in the mounting surface
for the four screws (provided).
2. Fasten with a screwdriver and wrench.
Note
Recommended torque on fastening screws for good seal:
1.1 N m
10 in-lbs
Recommended mounting: mount to panel, up to 5 m from the device. If alternate
mounting surface is used, it MUST be able to support four times the weight of the device.
Fasteners included: M5 screw, seal washer, M5 flat washer and nut. These fasteners are
required to maintain IP65 rating on remote lid.