Input 1: TC (int. CJC or
e
xt. 2-wire or 3-wire CJC)
Input 2: 2-wire, 3-wire or 4-wire
RTD
Input 1 (I1) and/or
input 2 (I2):
3-wire or 4-wire potentiometer
Input 1 (I1): 5-wire potentiome‐
ter
Input 2 (I2): 3-wire potentiome‐
ter
2. Connect the supply voltage to the terminals 3 (+) and 4 (-).
5+$57

For devices with HART communication, connect a ≥ 250 Ω resistor.
3
. Take the polarity into account. The device has reverse polarity protection.
Connecting
5.7 Connecting TR420
SITRANS TH100/TH100Slim/TH320/TH420/TR320/TR420/TF320/TF420
52 Compact Operating Instructions, 07/2021, A5E41865021-AE