ST750 GENERAL HANDBOOK
667/HB/33750/000 Page 68 Issue 6
The inner sheathing is removed to expose the individual cores that are connected to
associated terminals, leaving sufficient spare length for re-making off the ends
should this become necessary. Unused cores should be left with sufficient length to
enable them to be connected to any terminal should this subsequently become
necessary.
The ST750S, controller cabinet (Small outer-case) has 2 CET bars and the CET
bars are mounted directly to the controller cabinet. Each bar has 8 holes for fixing
cables; 4 upper and 4 lower fixing positions. This allows the CET rings and hose
clips to overlap each other. The cables must be identified as to their destinations
and additional Idents may be required on specific contracts.
The ST750L controller cabinet (Large outer-case) has 2 CET bars as standard, but
can be expanded to accommodate additional cables, and the CET bars are mounted
directly to the controller cabinet stool. Each bar has 6 holes on each side for fixing
cables. These holes are staggered to allow the CET rings and hose clips to overlap
each other. The cables must be identified as to their destinations and additional
Idents may be required on specific contracts.