13.4 Messages and troubleshooting measures Events and faults
13 - 16
© Siemens VDO Automotive AG Edition 07/2007
TD00.1381.00 132 102
{j FKFDUJPOáOPUá
QPTTJCMF
 00000005B3 A tachograph card cannot be ejected; the request is rejected.
Possible causes
Vehicle is moving
Download of data from the requested tachograph card is in
progress
Ignition is off (only ADR variant)
The tachograph card is being read or written on
The tachograph card is requested within the same minute
during which the tachograph card is correctly read in (after
insertion or after restart during activation).
Measures
Check whether the DTCO 1381 detects "drive"; if so, stop the
vehicle and repeat the process.
Check whether data is currently being downloaded; if so,
repeat the process after the download is finished.
Check whether the ignition is on, turn ignition on if necessary
(only ADR variant).
Repeat process.
If the error message continues to appear despite these measures,
replace the DTCO 1381.
{j 
{j 
SFDPSEJOHá
JODPOTJTUFOU


00000005B3 While reading-in a tachograph card, an inconsistency is found in
the links within the date data.
Measures
Check tachograph card.
Analyze data structure.
{j
{j
DBSEáFSSPS 

00000005B3 The inserted card cannot be read or written to.
Possible causes
Card inserted incorrectly
Card is defective
Measures
Check to make sure the tachograph card is valid.
Make sure the tachograph card is correctly inserted and insert
properly if needed.
Check tachograph card.
Check if another tachograph card is read correctly.
DTCO 1381 display
Picto. Error text MC Error code Meaning, cause and measures

Table of Contents