Events and faults 13.4 Messages and troubleshooting measures
Edition 07/2007 Technical Description DTCO 1381 13 - 27
TD00.1381.00 132 102
13.4.5 Event warning messages
The DTCO 1381 detects events and outputs a corresponding
warning message.
The warning message consists of:
• Entry in the DTCO 1381 data memory
• Entry on the inserted tachograph cards
• Warning message on the display of the DTCO 1381
• TCO status output on the CAN bus and on the info interface
• Signal to output D4 (TCO warning output)
If the DTCO 1381 is in the calibration mode, some messages will be
accompanied by an additional pictogram (letter) in the display; see
column "AP".
The error code can be read-out over the diagnosis interfaces (CAN or
K-Line) with a test device, but it will not be shown on the display of
the DTCO 1381.
DTCO 1381 display
Picto. AP Error text MC Error code Meaning, cause and measures
n " QPXFSá
JOUFSSVQUJPO
8000000004 The operational voltage of the DTCO 1381 was outside of
the specification.
Possible causes
•Overvoltage
•Undervoltage
Measures
– Check the voltage supply of the DTCO 1381; correct the
following if necessary:
a) Connection plug and cable (pin assignment, poor con-
nection, loose contact).
b) Voltage on terminals 30 and 15; within the specified
range?
c) Voltage behavior on terminals 30 and 15 during
starting; within the specified range?
– Check functionality of the DTCO 1381.
Replace any defective components.
2)
1)
These warning messages will be displayed repetitively every hour until the cause is withdrawn.
2)
These warning messages are not saved in the date memory during calibration mode.