13.4 Messages and troubleshooting measures Events and faults
13 - 28
© Siemens VDO Automotive AG Edition 07/2007
TD00.1381.00 132 102
n # QPXFSá
JOUFSSVQUJPO
8000002004 The motion sensor’s voltage supply was interrupted.
Measures
– Check KITAS 2171 sensor cable and correct the following
if necessary:
a) Pin assignment
b) Connection (imperfect contact)
c) Specifications
– Check voltage behavior on terminals 30 and 15 during
starting; within the specified range?
– Check KITAS 2171.
– Check DTCO 1381 (input B3).
Replace any defective components.
2)
p " TFOTPSáGBVMU 8000002180 Error during sensor communication.
Possible causes
• No real-time signal
Measures
– Check KITAS 2171 sensor cable and correct the following
if necessary:
a) Pin assignment
b) Connection (imperfect contact)
c) Specifications
– Check KITAS 2171.
– Check DTCO 1381 (input B3).
Replace any defective components.
1)
p # TFOTPSáGBVMU 8000002280 Error during sensor communication.
Possible causes
• Difference of the motion sensor impulses
• Transmission error
Measures
– Check KITAS 2171 sensor cable and correct the following
if necessary:
a) Pin assignment
b) Connection (imperfect contact)
c) Specifications
– Check KITAS 2171.
– Check DTCO 1381.
Replace any defective components.
1)
DTCO 1381 display
Picto. AP Error text MC Error code Meaning, cause and measures
1)
These warning messages will be displayed repetitively every hour until the cause is withdrawn.
2)