EDM eco
Unit settings Operating instructions
36 © Siemens VDO Trading GmbH TU00-1404-0311020
Setting speed warning
Using the EDM eco you can specify a speed alarm value. If this alarm value is exceeded, the
driver will receive an audible and visual warning signal (-> 20) to tell him to reduce his speed.
If you wish to deactivate the speed warning, simply reset the speed alarm value to "000".
1 Press the key and the key at the same time to switch to the unit
settings.
The first menu item 86(U6HW83 will be displayed automatically.
2 Select the6\6W(6HW83>6HW836\6W(>63($6HW83(-> 27) menu item
(-
> 31).
If PIN protection has already been activated, you will automatically be asked
to enter the system PIN number in the place indicated (-> 24).
3At 63($ enter the required speed alarm value.
Values are entered in the same way as PIN numbers (-> 24).
4 Confirm the value using the key.
5 After you have completed all entries, press the key until you return to the
normal display mode.