Remote Manual
SDM3045X Digital Mulimeter
RC06034-E01A
2017 SIGLENT TECHNOLOGIES CO.,LTD
Question and Answer IconNeed help?

Do you have a question about the SIGLENT TECHNOLOGIES CO.,LTD SDM3045X and is the answer not in the manual?

SIGLENT TECHNOLOGIES CO.,LTD SDM3045X Specifications

General IconGeneral
BrandSIGLENT TECHNOLOGIES CO.,LTD
ModelSDM3045X
CategoryMultimeter
LanguageEnglish

Summary

SCPI Command Structure and Syntax

SCPI Language Introduction

Explains SCPI as an ASCII-based programming language for instruments.

SCPI Syntax Conventions

Details the rules for command syntax, including braces, bars, and brackets.

SCPI Command Separators

Describes the use of colons and semicolons to separate commands and parameters.

SCPI MIN, MAX, DEF Parameters

Explains how MIN, MAX, and DEF can substitute specific parameter values.

Querying SCPI Parameter Settings

Details how to use a question mark (?) to query current parameter values.

IEEE-488.2 Common SCPI Commands

Outlines standard commands beginning with an asterisk for common functions like reset.

SCPI Parameter Data Types

Describes different data formats for parameters: numeric, discrete, and boolean.

SCPI Command Reference

SCPI ABORt Command

Aborts a measurement in progress, returning the instrument to the trigger idle state.

SCPI FETCH? Command

Waits for measurements to complete and copies them to the output buffer.

SCPI INITiate Command

Sets the trigger state to "wait for trigger" and clears previous measurements.

SCPI OUTPut:TRIGger:SLOPe

Selects the slope (rising or falling) for the output signal on the BNC connector.

SCPI R? Data Retrieval

Reads and erases measurements from reading memory up to a specified count.

SCPI READ? Command

Reads and erases measurement results from storage up to a specified count.

SCPI SAMPle:COUNt Setting

Specifies the number of measurements (samples) taken per trigger.

SCPI UNIT:TEMPerature Setting

Selects units (°C, °F, or Kelvin) for temperature measurements.

Instrument System Commands

CALCulate Subsystem Overview

Configures calculation functions like limits, histograms, and averages.

CALCulate:LIMit Subsystem

Specifies measurements and indicates when a limit has been exceeded.

CALCulate:HISTogram Subsystem

Configures the histogram display and data collection.

CALCulate:SCALe Subsystem

Scales ACV and DCV measurements, including dB and dBm functions.

CALCulate:AVERage Subsystem

Calculates measurement statistics such as mean, min, max, and standard deviation.

CONFigure Subsystem

Provides the most concise way to configure measurement functions, range, and rate.

DATA Subsystem

Allows configuration and removal of data from the instrument's reading memory.

MEASure Subsystem

Simplest way to program measurements, using default parameters and sending results directly.

SENSe Subsystem Introduction

Configures measurement functions like current, voltage, resistance, etc.

SYSTem Subsystem Configuration

Configures system-level settings such as beep, IP address, and subnet mask.

TRIGger Subsystem Configuration

Configures triggering parameters that control measurement acquisition.