Distributed Power Module
MODEL 5499
Installation and
Operations Manual
Document 151253
Rev M
151253:M ECN 15-0644

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the SILENT KNIGHT 5499 and is the answer not in the manual?

SILENT KNIGHT 5499 Specifications

General IconGeneral
Frequency50/60 Hz
Output Voltage24 VDC
Operating Temperature32°F to 120°F (0°C to 49°C)
Input Voltage120 VAC, 60 Hz
Battery Charger7.0 A

Summary

Introduction to Silent Knight Model 5499

Key Product Configurations

Overview of the 5499's configurable input, output, and auxiliary power settings.

Signal Input and Output Handling

Describes how the 5499 processes input signals and drives output notification circuits.

Auxiliary Power and Trouble Features

Details the auxiliary power output and the Form C trouble relay functionality.

Synchronization and Temporal Code Support

Explains support for synchronized appliances and ANSI temporal coded outputs.

UL Requirements for Model 5499

System Overview of the 5499 Module

Terminal Descriptions and Electrical Ratings

Lists and explains all terminals on the 5499 board and their electrical specifications.

Signal Input Terminal Functions

Details the purpose and operation of the 5499's signal input terminals.

Notification Appliance Circuit Terminals

Describes the output terminals for notification appliance circuits and their configurations.

Installation Procedures for Model 5499

Mounting and Water Damage Prevention

Guidelines for mounting the unit and preventing water ingress into the enclosure.

Wire Routing Best Practices

Recommendations for routing wires to prevent noise interference and ensure system integrity.

Current Requirements for Operation

Specifies the current draw from the host panel and battery for standby and alarm conditions.

Connecting to Control Panel and Trouble Relay

Instructions for wiring the 5499 to a control panel and utilizing the trouble relay.

Notification Appliance Wiring: Class A & B

Detailed wiring diagrams and procedures for Class A and Class B supervised circuits.

Ground Fault Detection and Battery Connection

Information on enabling/disabling ground fault detection and connecting the unit's batteries.

DIP Switch Settings for Configuration

Guide to setting DIP switches for various operational configurations like synchronization and temporal codes.

Sample Applications of Model 5499

Notification Power Application Examples

Illustrative diagrams showing different notification power distribution configurations.

Non-Resettable Power Application

Wiring example for a non-resettable auxiliary power output configuration.

Door Holder Application Wiring

Diagram showing how to wire door holders for emergency door release.

Troubleshooting Model 5499

Understanding Device LEDs

Explains the meaning of the LEDs on the 5499 for fault indication.

Common Trouble Conditions and Causes

Lists potential trouble conditions, their causes, and system responses.

Earth Fault Resistance Parameters

Table detailing earth fault resistance values for detection on various terminals.

Control Panel Removal and Replacement Procedures

Step-by-step instructions for safely removing and replacing the control panel module.

UL Listed Notification Appliances Compatibility

Compatible Notification Appliance List

A comprehensive list of UL listed notification appliances compatible with the 5499.

Fire Product Warranty and Return Policy

General Warranty Terms and Conditions

Outlines the standard warranty period and exclusions for fire products.

Repair and RMA Procedure

Details the process for returning products for repair or credit, including RMA requirements.

Advanced Replacement Policy

Explains the option for advance replacement of defective printed circuit boards.

Manufacturer Warranties and Limitation of Liability

Related product manuals