8) Insert the plug into a mains power socket and switch on the appliance using
the on/off switch i. The appliance heats up.
9) Press the “Large” latte button 3 and the “Small” latter button w at
the same time as soon as the device is heated up. The appliance starts the
descaling process. All of the control lamps light up in sequence. Steam and
hot water come out of the milk nozzle 0.
The descaling process completes after around 10 minutes, and all of the
control lamps come on permanently.
10) Remove the rest of the descaler solution from the water tank z and clean
the water tank (see section “Cleaning the water tank”).
11) Empty the container on the drip grille 8 and place it back into the appliance.
12) Fill the water tank z with fresh water up to the MAX mark and insert it back
into the appliance.
13) Brew 2 “Double” espressos and 2 “Large” lattes so that the pipes are rinsed
out with fresh water.
The appliance can now be used again as normal. After another 500 uses the
descaling warning will be shown again.