1.2.3.6 Tx Power
1. Select
Tx Power/Mod
page.
2. Select Channel 0.
3. Select the 0.5W power level.
4. Press the
PTT
button.
5. Adjust the Tx Final Value slider for a power output of 0.5W.
6. Repeat step 5 for the remaining 3 Channels (1, 2, & 3).
7. Select the
1W
power level.
8. Adjust the Tx Final Value slider for a power output of 1W.
9. Repeat step 8 for the remaining 3 Channels (2, 1& 0).
10. Select the
5W
power level.
11. Adjust the Tx Final Value slider for a power output of 5W.
Note that the supply current is less than 2.5A.
12. Repeat step 11 for the remaining 3 Channels (1, 2, & 3).
13 Press “Calibrate TX PA Current” button to automatically set the maximum current limit.
14 Release the PTT button.