| 15
Installation | Loop M User Manual
Naviop CAN connector
The Naviop CAN connector is used for connecting the Egon+ board to the Naviop CAN
backbone and to supply the processor with power. The ID of the Egon+ board is determined
by the ID of the cable.
• Loop M ships with one Egon+ board and a drop-cable labelled with CAN ID:1.
• Loop M+ ships with two Egon+ boards and drop-cables labelled with CAN ID:1 and CAN ID:2.
The Egon+ board requires its own 12 V DC power supply, protected by a 2A fuse.
A
12 V DC
E
B
F
C
D
A Naviop CAN connector
B Red wire (DC positive) and black wire (DC negative)
C Naviop CAN drop-cable marked with the ID of the cable/Egon+ board
D 12 V DC power supply
E Naviop CAN backbone
F Fuse 2A
Egon+ board power input
Warning: The Egon+ board is equipped with 12 V DC rated relays. The
input voltage should match the voltage rating of the relays.
Connect the boat’s main power supply to the screw terminal (M8 stud). The cable must be
of enough size to carry the maximum current of all loads connected to the Egon+ board
and have a fuse/circuit breaker rated to protect the cable. Voltage drop should be kept to a
minimum.
¼ Note: DC negative should be connected to the controlled and/or monitored equipment.
C
12 V DC
B
D
E
A
F
A 12 V DC positive bus
B Power input cables (the cable must be able to carry the maximum current of all loads)
C Power input terminals (2x M8 studs)
D Main battery switch
E Overcurrent protection (fuse or circuit breaker)