3/4
4.2- Safety input function: Parameters
- When using a resistive safety edge, the latter must be wired onto safety input 1. The opening safety device (
= ) stops then recloses partially (non
configurable action).
Configuration of safety input 1 (safety edge*): Parameter
(factory setting = )
4.3- Safety action upon closing: Parameter
(factory setting = )
- The safety action at opening (
= ) is not configurable (stopage followed with partial door reopening). However, safety actions upon closing (
= ) can be configured.
Select parameter
by pressing several time on the
key From the release of the key, the display indicates and flashes.
- For programming the “UP / STOP / DOWN” order, select using the key
or
the functionality then program the key associated with this order.
- For programming the auxilliary output order, select using the key
or
the functionality then program the key associated with this order.
4.4- Configuration of the self-testing function: Parameters
- The self-test function is used to check proper operation of the safety accessories automatically at the end of closing.
Self-testing safety input 1: Parameter
(factory setting = )
4.5- Programming remote controls : Parameter
- According to the type of operation chosen in chapter 3.1, the value of the parameter does not produce the same effects.
Sequential mode
3 buttons mode
Ensure you configure the safety input used for the appropriate self-test: safety 1: P1+P5, safety 2: P2+P6, safety 3: P3+P7 Once the safety accessories
are connected and the safety inputs configured, check manually the proper operation of the accessories before the final start up of the facility.
Configuration of safety input 2 (photocell*): Parameter (factory setting = )
Configuration of safety input 3: Parameter
(factory setting = )
Self-testing safety input 2: Parameter
(factory setting = )
Self-testing safety input 3: Parameter
(factory setting = )
No accessories connected to safety input 1 (default mode)
Accessory connected to safety input 1 enabled when opening the door
Accessory connected to safety input 1 enabled when closing the door
ADMAP** safety: active upon closing + forbids starting at opening
Contact for connecting an emergency stop device
No accessories connected to safety input 2 (default mode)
Accessory connected to safety input 2 enabled when opening the door
Accessory connected to safety input 2 enabled when closing the door
ADMAP** safety: active upon closing + forbids starting at opening
Contact for connecting an emergency stop device
No accessories connected to safety input 3 (default mode)
Accessory connected to safety input 3 enabled when opening the door
Accessory connected to safety input 3 enabled when closing the door
ADMAP** safety: active upon closing + forbids starting at opening
Contact for connecting an emergency stop device
No self-test of the accessory connected (default mode)
Self-test for photocells by power supply cutting. Caution : the transmitting cell
must be supplied on terminals 10/12 and the receiver cells on terminals 10/11).
Self-test for accessory fitted with a TEST input (cells or sensor bar).
No self-test of the accessory connected (default mode)
Self-test for photocells by power supply cutting. Caution : the transmitting cell
must be supplied on terminals 10/12 and the receiver cells on terminals 10/11) :
Self-test for accessory fitted with a TEST input (cells or sensor bar).
Opening / Closing Command (default mode).
Auxiliary output control
(driving the accessory
connected to the AUX output).
Open command
Close command
Stop command
Auxiliary output control (driving the accessory
connected to the AUX output).
opening
Stop
closing
Auxilliary
Opening
Stop
closing
Stop the door
Stop, then total reopening of the door (default mode)
Stop then partial reopening of the door(2 seconds operation)
No self-test of the accessory connected (default mode)
Self-test for photocells by power supply cutting. Caution : The transmitting cell
must be supplied on terminals 10/12 and the receiver cells on terminals 10/11).
Self-test for accessory fitted with a TEST input (cells or sensor bar).
Self-test for resistive sensor bar (value comprised between 4 and 12 K
Self-test for optical sensor bar
Select parameter
by pressing several time on the
key From the release of the key, the display indicates and flashes.
- For programming the “UP” order, select using the key
or
the functionality
then program the key associated with this order.
- For programming the “DOWN” order, select using the key
or
the functionality
then program the key associated with this order.
- For programming the “STOP” order, select using the key
or
the functionality
then program the key associated with this order.
- For programming the auxilliary output order, select using the key
or
the functionality
then program the key associated with this order.