Depth
of
field
-
with all SINAR
models
Afier
locating
and
focusing
on
the
plane
of
maximum
sharpness,
stop
down
the
lens
as
far as
necessary
to extend
sharpness
at
right angles
to
this
plane.
The simplest
and
quickest way
is with the
SINAR
depth
of
field
scale:
-
At
full aperture
focus
on
the most
distant
subject
point
required
sharp
(i.e.
focused
with the
shortest
camera
extension).
-
Without
changing
the
focus setting,
zero
the
depth
of field
scale
(arrow
against
index).
-
At
full aperture
focus
on
the nearest
subject
point
required
sharp
(i.e.
focused
with
the
longest camera
extension).
-
Read
off
the
working
aperture
now shown
on
the scale
(e.9.
here
'f/22'1
and
set
this
on
the lens.
-
Turn
the
fine
focusing
drive
2 back
through
two lens stop
intervals
on
the
depth
of
field scale
(shortening the camera
extension
-
to
f/'l 1
in this
case).
This
then
yields
optimum
focus.
Further
accessories
The SINAR
COLOR
CONTROL
filter system
The SINAR
COLOR
CONTROL
filter system
100 and 125
with over
200 different
dyed-in-the-mass
plastic
filters
plus
polarising
filters
meets
all needs
of
present-day
view camera
photography.
The filter
holder
'1
00
holds up
to three
1
00
mm f ilters at a
time. A
rapid clamping
screw
secures
adaptors
to
fit the holder
in the filter thread of
almost
any
lens.
The
filter holder
'l
00
further takes
clip-on
lens hoods of
various sizes.
The
filter system
125 comprises
125 mm filters
held in the filter
holder
1
(for
one
filter)
or 2
(taking
two
filters) similar
to the system
1
00
hold-
ers.
Fifter holders
1 and
2
also
clip
together and
rotate against each
other.
Further,
the filter holders
may be
mounted on any
SINAR stan-
dard
with
the bellows
holder and
rod or fitted
in the multipurpose
standard.
SINAR
exposure
meters and shutters
Moupting
exposure
meters
A
probe
holder built
into the
film holder
frame of
the metering back
takes
the
metering
probes
of the SINAR
exposure
meters.
The meter
itself is mounted
on
the
probe
holder via the
462.96.001
meter holder
plate.
O
With
the milling screw
secure
the meter
holder
plate
on the
probe
holder
or on one of
the side cover
panels
of
the standard.
O
Place
the meter on
the meter holder
plate
and
lock in
place.
O
Release
the lock on
the
probe
holder.
O
Insert the
probe
in
the
probe
holder,
with the SINAR
logo facing
to
the
rear, and
lock.
Automatic
SINAR
film
holder and
shutter
couplang
SINAR
backs
carry
a coupling
socket
for automatic
shutter
operation
via a
cable
linkage between
the camera
back
and
the shutter.
This au-
tomatically
closes the
SINAR
shutter
on
inserting a
film holder
in the
SINAR
back.
The connecting
points
are
marked.
With the
SINAR/COPAL
shutter
Once
the 521.91
bayonet
connector
is
adjusted,
screw
it tight on
the
back
and
leave
it there.
You can
then
quickly
switch
automatic
coup-
ling cables
without
readjustment.
A connector
can
link two
automatic
cables
to bridge
long extensions.
12
Fig.47