DC INVERTER U-MATCH AIR CONDITION MAINTENANCE
151
4. Remove the motor
power cable
● Use hand or forceps to
pull out the motor power
cable from mainboard
5. Remove the motor
●Use spanner and
screwdriver to remove the
bolts fixing the motor.
●Remove the motor from
motor support.
6. Install a new motor to
motor support
●Put the new motor to
correct position.
●Use spanner and
screwdriver to fix the motor
to motor support with bolts.
7. Connect the motor
power cable
● Connect the insert of
motor power cable to the
mainboard terminal in
reverse to the disassembly
procedures.
8. Assemble the fan
● Assemble the axial flow
fan to correct position and
fix it to the motor shaft in
reverse to the disassembly
procedures.
●Put the electric box cover
to correct position and fix it
onto the electric box
according to disassembly
procedures.