ASH-18AK
.
ASH-24AK
.
Shanghai Hitachi Electrical
Appliances Co,Ltd./Highly
Shanghai Hitachi Electrical
Appliances Co,Ltd./Highly
ASH210SV-C8LU ASH264SV-C8LU
rotary compressor rotary compressor
40 60
7.5 10.3
1725 2215
Capillary Capillary
Capacitor Capacitor
-7
℃≤
T
43
-7
℃≤
T
43
Aluminum fin-copper tube Aluminum fin-copper tube
7 Φ9.52
2-1.4 2-1.4
806×660×25.4 804X660X44
860 780
48 68
0.62 1.2
3.5 2.5
2790m3/h 3400m3/h
Axial fan –1 Axial fan –1
Φ473 Φ472
Auto defrost Auto defrost
T1 T1
II
IP24 IP24
3.8 3.8
1.2 1.2
56/54/52 56/54/52
66/64/62 66/64/62
913X680X378 950X700X412
994X720X428 1100X755X450
46/50 59/64
R410/1.6 R410/1.85
44
50 50
Liquid Pipe (mm)
Φ
6
Φ
9.52
Gas Pipe (m m )
Φ
12
Φ
16
Height (m)
10 10
Length (m) 1
5 15
Fan Motor Speed (rpm) (H/M/L)
Output of Fan Motor (W)
Condenser
Pipe Diameter (mm)
Rows-Fin Gap(mm)
Coil length(l) x height(H) x coil width(L)
Net Weight /Gross Weight (kg)
Permissible Excessive Operating
Pressure for the Suction Side(MPa)
Sound Pres sure Level dB (A) (H/M/L)
Sound Power Level dB (A) (H/M/L)
Dimension (W/H/D) (mm)
Dim ens ion of Package (L/W/H)(m m)
Outer
Diameter
Refrigerant Charge (kg)
Outdoor
unit
Connecti
on Pipe
Gas additional charge(g/m)
Length (m)
Max
Distance
Model of Outdoor Unit
Com pres s or Manufacturer/tradem ark
Compressor Model
Compressor Type
L.R.A. (A)
Compressor RLA(A)
Compressor Power Input(W)
Overload Protector
Throttling Method
Starting Method
Working Temp Range (
)
Fan Motor RLA(A)
Fan Motor Capacitor (uF)
Air Fl o w Volum e o f Ou td o o r U nit
Fan Type-Piece
Moisture Protection
Permissible Excessive Operating
Pressure for the Discharge Side(MPa)
Fan Diameter (mm)
Defrosting Method
Climate Type
Isolation
The above data is subject to change without notice. Please refer to the nameplate of the unit.