To perform a LiveSCAN using a SNYPER Graphyte, follow the steps below:
Step 1. Conduct a survey of any type using an omni-directional antenna.
Step 2. When the survey is complete view the results acquired. Use the LEFT/RIGHT
buttons to nd the survey results of the cell on which a LiveSCAN is to be executed.
Step 3. Connect an appropriate antenna for the survey. This might be the supplied
omnidirectional antenna for general signal strength measurement or a directional
antenna in order to locate the direction in which the cell being scanned is located. It is
recommended that the antenna which is to be installed be used as then the SNYPER
Graphyte will see the same signal strengths as the equipment being installed.
Step 4. Press OK to initiate LiveSCAN.
Step 5. The option to log the LiveSCAN measurements is offered. Select ‘On’ or ‘Off’
using the UP/DOWN buttons. Press OK to begin LiveSCAN.
Figure 33. LiveSCAN logging
On: Performs a LiveSCAN and logs all captured results. Results
will be available to download in .csv format by following the PC
Connect steps on page 39.
The rst LiveSCAN survey log le is named LL000000.csv, the
second LL000001.csv, etc. There is NO .htm le stored for
LiveSCAN logging.
Off: Performs a LiveSCAN without logging results.
Performing a LiveSCAN