Number of Survey
Cycles in Log
Test Condition File
Size Observed (KB)
Rule of Thumb
Guidance (KB)
Survey Capacity
1 62 78 84
5 118 148 73
10 155 194 55
15 188 235 46
25 250 313 34
50 404 505 21
75 637 796 13
100 904 1130 9
200 1467 1834 6
500 3782 4728 2
Default settings used in the example are shown below.
» Pre-set status: Pre-set interval between one survey nishing and the next
starting - 0 mins i.e. automatic back to back survey testing
» File Status: CSV and HTML les created
» LiveSCAN Logs: No LiveSCAN logs created due to variability of disk usage vs.
time
» Debug Logs: No Debug logs created due to variability of disk usage vs. time
Table 1. SNYPER-LTE Graphyte survey storage
NOTE: These results could vary considerably between locations and are shown as an example
of a semi-urban setting. The size of the log will be totally dependant on the number of cells
discovered by the SNYPER-Graphyte. As a very general rule, the more urban the environment
the greater the number of cells likely to be discovered.