- Page 28
-
ITEM
FIELD
FACTORY
AUTHORISED
SERVICE
CENTRE
WHEN
REEVED
EACH WORK
SHIFT
Every
3 Months
Every
12 Months
SAFETY EQUIPMENT
x
x
ROPE CONDITION
x
x
OVER-/UNDERLOAD
DEVICE
x
x
SKY LOCK
- Coupling nuts & Bolts
Note (2)
x
Note (1) & (4)
x
Note (3)
Note (3)
HOIST UNIT
-
Coupling nuts & Bolts
-
Rope Housing Drain
x
x
x
x
x
x
WORK PLATFORM
x
x
RIGGING
x
x
ELECTRICAL
CONNECTIONS
x
x
Table 1 - Periodic inspection frequency
Table notes:
1.
Frequency of inspection is dependent upon the “Work Environment”:
Normal - check weekly
Abrasive or caustic - check daily
Freezing - check every two hours
2.
Inspection method is different than Note 1. See instructions in Section 5.
3.
Return to Factory authorized service Centre:
every three months if used in contaminated or freezing environments
every six months if used in a normal environment
See instructions in Section 5.
4.
Check every four hours when work environment includes adhesives.

Table of Contents