Opening and Closing SMA Solar Technology AG
56 SMC9-11TLRP-IEN100640 Installation Guide
7 Opening and Closing
7.1 Safety
7.2 Opening the Inverter
1. Disconnect the line circuit breaker and secure against re-connection.
2. Pull the Electronic Solar Switch downwards, slightly
towards the wall.
3. Ensure there is no current at any DC cables using a
clip-on ammeter.
If there is a current present, check the
installation.
DANGER!
Risk of lethal electric shock!
Observe the following before opening the inverter:
Ensure the AC side is not live.
Ensure the DC side is not live.
NOTICE!
Electrostatic discharges can damage the inverter.
Internal components of the inverter can be irreparably damaged by electrostatic
discharge.
Ground yourself before touching a component.