Opening and Closing SMA Solar Technology AG
60 SMC9-11TLRP-IEN100640 Installation Guide
5. Switch on the line circuit breaker.
6. Check whether the display and the LEDs indicate
normal operating mode (see section
6”Commissioning” (page55)).
The inverter is now closed and in operation.
NOTICE!
Manipulating the connector in the handle can damage the Electronic Solar
Switch!
The connector inside the handle must remain movable in order to ensure proper contact.
Tightening the screw voids all warranty claims and creates a fire risk.
•Do not tighten the connector screw in the Electronic Solar Switch handle.
NOTICE!
Damage to Electronic Solar Switch!
If not plugged correctly, the Electronic Solar Switch can be damaged by high voltages.
Connect the holder firmly on to the socket of the Electronic Solar Switch.
Make sure that the device is securely in place.