SMA Solar Technology AG Maintenance and Cleaning
Installation Guide SMC9-11TLRP-IEN100640 61
8 Maintenance and Cleaning
8.1 Checking Heat Dissipation
8.1.1 Cleaning the fan
If the fan guards are only soiled with loose dust, they can be cleaned using a vacuum cleaner. If you
do not achieve satisfactory results with a vacuum cleaner, dismantle the fans for cleaning.
Procedure
1. Disconnect the inverter from both the DC and AC connections as described in section
7.2”Opening the Inverter” (page56).
2. Wait for the fans to stop rotating.
Cleaning the Fan Grills
3. To remove the fan grills:
Press both latches on the right of the fan grill to
the right using a screwdriver and loosen from
the bracket.
Carefully remove the fan grill.
4. Clean the fan grill with a soft brush, a paint brush,
a cloth or compressed air.
Cleaning the fan
5. Press the front latches backward and the rear latch
forward.