EasyManua.ls Logo

SMA 10000TL - Page 86

SMA 10000TL
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Data SMA Solar Technology AG
86 SMC9-11TLRP-IEN100640 Installation Guide
General data
EC Declaration of Conformity Enclosed documentation package
Download area www.SMA.de/en
Dimensions (W x H x D) 468 mm x 613 mm x 242 mm (approx.)
Weight approx. 35 kg
Protection rating in accordance with
DIN EN 60529
IP65
Climatic conditions according to DIN EN 50178:1998-04:
Location of type C: Class 4K4H
Extended temperature range:
-25 °C to +60 °C
Extended humidity range:
0 ... 100 %
Extended air pressure range:
70 kPa to 106 kPa
Transport of type E: class 2K3
Temperature range:
– 25 °C ... +70 °C
Operation temperature range – 25 °C ... +60 °C
Max. operating altitude 3000 m above mean sea level
Topology Transformerless
Fan connection
Designed for safe disconnection in accordance with
DIN EN 50178:1998-04
Protection class I
Noise emission (typical) 42 dB(A) 45 dB(A) 46 dB(A)
Protective function DC side
All-pole disconnection unit on the DC input side Electronic Solar Switch,
DC plug system SUNCLIX
Overvoltage protection Thermally monitored varistors
Personnel protection Insulation monitoring (R
iso
> 1 M )
Pole confusion protection Via short-circuit diode
SMC
9000TLRP-10
SMC
10000TLRP-10
SMC
11000TLRP-10

Table of Contents

Other manuals for SMA 10000TL

Related product manuals