SMA Solar Technology AG Parameter lists
Technical Description SI5048-TEN093630 171
19.2.6 Password Setting (280#)
You can find detailed information about this menu in chapter 10.5”Entering the installer password”
(page73).
15 SlpStpTm Stop time for switching off
at night (sleep mode)
05:00:00
hh:mm:ss
23 Box Type of Multicluster Box
used
MC-Box-6 Multicluster
Box 6.3
MC-Box-9 Multicluster
Box 9.3
MC-Box-12 Multicluster
Box 12.3
24 ClstMod Cluster type in multicluster
operation
Single
Cluster
MainCluster
ExtensionClst
1
ExtensionClst
2
ExtensionClst
3
25 ClstAdr Cluster address
28 ChrgCtlOp Typ of DC charging
device
Auto Automatic Auto
DCOnly Battery charger
only
SMA Sunny Island
Charger
30 RnMod "Run mode"
Reaction in case of
failures
RunAlways always
available
RunAlways
StopAlways Stop in case of
device failure
31 CurCtl Location of the current
control
External External
Internal
Number Name Description Value Description Default
value