6 Mounting
SMA Solar Technology AG
Operating manual STP110-60-BE-en-16 31
3. Drill the bore holes (Ø 12 mm) at the marked areas.
4. Attach the mounting bracket to the wall using the heavy-duty anchors.
5. Remove the sealing screws on the sides of the
inverter using a flat-blade screwdriver (4mm).
6. If the inverter is to be hooked into the mounting
bracket using a lifting gear, screw the eye bolts into
the 2 upper threaded holes on the right-hand and
left-hand side of the inverter and attach the lifting
gear to them. The lifting gear must be suitable to
take the weight of the inverter.
7. If the inverter is to be hooked into the mounting
bracket without using a lifting gear, screw the
carrying handles as far as they will go into the
threaded holes on the right-hand and left-hand side
until they lie flush with the enclosure. When doing
so, ensure that the carrying handles are screwed
into the threaded holes so that they are perfectly
straight. If the carrying handles are not screwed in
straight, this can make it more difficult or even
impossible to unscrew them later on and can
damage the threaded holes to the extent that
carrying handles can no longer be screwed into
them.