EasyManua.ls Logo

SMA SUNNY BOY 1.5 - Climatic Conditions

SMA SUNNY BOY 1.5
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Grid configurations TN-C, TN-S, TN-CS, TT(if V
N_PE
<30V), IT, Delta
IT, split phase
National standards and approvals, as per
01/2017*
AS4777, C10/11/2012, CEI0-21,
EN50438:2013, DINEN62109-1, G83/2,
IEC62109-2, NBR16149, NEN-EN50438,
NRS097-2-1, RD1699/413, VDE 0126-1-1,
VDE-AR-N4105, VFR2014
* IEC62109-2: In order to meet the requirements of this standard, there must be a link to SunnyPortal
with the fault alert via e-mail activated.
Climatic Conditions
Installation in accordance with IEC60721-3-4, Class4K4H
Extended temperature range -40°C to +60°C
Extended humidity range 0% to 100%
Extended air pressure range 79.5kPato106kPa
Transport in accordance withIEC60721-3-4, Class2K3
Extended temperature range -25°C to +70°C
Equipment
DC connection SUNCLIX DC connector
AC connection Spring-cage terminal
Speedwire interface As standard
Webconnect interface As standard
WLAN As standard
DC Load-Break Switch
Electrical endurance in the event of short circuit,
at nominal current of 10A
At least 50switching operations
Maximum switching current 35A
Maximum switching voltage 800V
Maximum PV power 11kW
Torques
Screws wall mounting Hand-tight
Screws connection cap 3.5Nm
SUNCLIX swivel nut 2.0Nm
AC swivel nut Hand-tight
15Technical Data