13 Technical Data
SMA Solar Technology AG
Operating manual SBxx-1AV-41-BE-en-12 103
SB5.0-1AV-41 SB6.0-1AV-41
Maximum short-circuit current,
input B*
20 A 20 A
Maximum reverse current into
the PV array
0A 0A
Number of independent MPP
inputs
2 2
Strings per MPP input 2 2
Surge category in accordance
with IEC60664-1
II II
* In accordance with IEC62109-2: ISC PV
AC Output
SB5.0-1AV-41 SB6.0-1AV-41
Rated power at 230V, 50Hz* 5000W 6000W
Maximum apparent AC power at cosφ=1** 5000VA 6000VA
Rated grid voltage 230V 230V
Nominal AC voltage 220V/230V/240
V
220V/230V/240
V
AC voltage range*** 180V to 280V 180V to 280V
Nominal AC current at 220V 22.8A 26.1A
Nominal AC current at 230V 22A 26.1A
Nominal AC current at 240V 21A 25A
Maximum output current**** 22.8A 26.1A
Total harmonic distortion of the output current
with total harmonic distortion of the AC voltage
<2%, and AC power >50% of the rated power
≤3% ≤3%
Maximum output current under fault conditions 29A 29A
Inrush current <20% of the nominal
AC current for a
maximum of 10ms
<20% of the nominal
AC current for a
maximum of 10ms
Rated power frequency 50Hz 50Hz
AC power frequency*** 50Hz/60Hz 50Hz/60Hz
Operating range at AC power frequency 50Hz 45Hz to 55Hz 45Hz to 55Hz
Operating range at AC power frequency 60Hz 55Hz to 65Hz 55Hz to 65Hz
Power factor at rated power 1 1