SMA America, LLC Maintenance
SB50US-80US-IA-en-36 SB50US-80US-IA-en-36 89
4. Check the DC varistors (A) for discoloration and visible damage.
If one of the DC varistors is discolored or damaged, replace all DC varistors:
5. Disconnect the DC varistors:
Disconnect the string connectors of all ungrounded DC cables from the PV array.
Remove the four fuse extractors with the string fuses from the fuse holders (B) of the DC
disconnect.
Remove the four string fuses from the fuse extractors.
Insert the four fuse extractors without the string fuses into the fuse holders (B) of the DC
disconnect.
6. Ensure that no voltage is present at the DC varistors.
If no voltage is present, replace all DC varistors:
Insert the insertion tool into the rectangular
opening of the terminal.
Remove the DC varistor.
DANGER
Danger to life due to short circuits in the DC varistors
Death or serious injury due to electric shock
Check whether current is flowing the DC cables.
Tip: Use a current clamp to measure the current.
Only use spare parts from SMA
Always replace the entire set of DC varistors.
Order number in Section 12 ”Spare Parts and Accessories” (page 101).