6 Maintenance
SMA Solar Technology AG
Maintenance ManualSCCPXT-E7-WA-en-3756
6.4.2.6 Checking the Seals
Figure 17: Section drawing with top view of a door seal (example)
Position Designation
A Seal
B Side panel
C Sealing area
D Hinge
E Door
F Frame construction
Required maintenance material (not included in the scope of delivery):
☐ A suitable water-free, heat-resistant lubricant
☐ Talcum, petroleum jelly or wax for maintaining the seals
DANGER
Danger to life due to electric shock or electric arc if live components are touched
• Switch off the inverter and wait at least 15minutes before opening it to allow the capacitors to discharge
completely.
• Disconnect the inverter (see Section4, page26).
Procedure:
1. Check whether the seals in the sealing area show any damage.
If seals are damaged, contact us (see Section9 "Contact", page68).
2. Apply talcum, petroleum jelly or wax to seals. This will prevent frost damage.
3. After removing the side panels: check whether the side panel seals display any damage in the sealing area.
If seals are damaged, contact us (see Section9 "Contact", page68).
6.4.2.7 Checking the Latches, Door Stops and Hinges
Required maintenance material (not included in the scope of delivery):
☐ A suitable, water-free and heat-resistant lubricant, e.g. WD40
☐ Non-greasing antifreeze agent, e.g.PS88