15.4 Messages concerning Active Power Limitation in the
System Logbook
Problem Cause and corrective measure
Message in the system logbook:
Supplied power has exceeded the
permitted value several times.
Although the function Limitation of active power feed-
in is activated, more than the maximum permitted active
power has been fed into the utility grid.
Corrective measures:
• Ensure that the feed-in meter used complies with the
requirements (see the installation manual of the
SunnyHomeManager).
• Ensure that the feed-in meter is configured correctly
(see Section8.6, page68).
• Ensure that the BLUETOOTH connection between all
the devices in the system is good. You can check the
connection quality with SunnyExplorer (see
SunnyExplorer user manual). If necessary, use the
SMAradio-controlled socket as repeater.
• Ensure that the parameter Operating mode active
power is set to the value Active power limitation
P via system control for all inverters.
Message in the system logbook:
Act. power limitation deactivated
due to incorr. configuration.
The function Limiting of the active power feed-in was
deactivated by SunnyHomeManager because the sys-
tem configuration in SunnyPortal was faulty.
Corrective measures:
• This message can appear while making changes to
the SunnyHomeManager system, e.g. upon device
replacement. In this case, no action is needed.
• If the message appears over an extended time
period, contact the Service (see Section16,
page142).
Message in the system logbook:
Disturbance:
act. power limitation activated w/
o regard to own consumption
The function Limiting of the active power feed-in is
faulty because there is no data from the feed-in meter. Risk
of yield loss because the self-consumption of the house-
hold cannot be taken into account.
Corrective measures:
• Ensure that the feed-in meter is working and
correctly connected.