9.2.3 Activating/Deactivating Data Collection
You can set whether or not the SunnyPortal is to collect data from the radio-controlled socket. If
you would like to control loads via the radio-controlled socket, you must activate data collection. If
you deactivate data collection, no radio-controlled socket data is displayed in SunnyPortal and
you cannot control any loads via the radio-controlled socket.
Procedure:
1. Call up the properties of the radio-controlled socket (see Section8.2, page66).
2. Select [Edit].
☑ The menu for setting the device properties opens.
3. To activate data collection, activate the checkbox Active.
4. To deactivate data collection, deactivate the checkbox Active.
9.2.4 Selecting the Load
In order that the radio-controlled socket can be controlled by the SunnyHomeManager, you must
assign a load to it. You will first need to create a load profile for the load (see Section9.3,
page79). If you have already installed a radio-controlled socket without assigning a load, you
can subsequently assign this radio-controlled socket to the required load when creating the load
profile.
Procedure:
1. Call up the properties of the radio-controlled socket (see Section8.2, page66).
2. Select [Edit].
☑ The menu for setting the device properties opens.
3. Select the connected load from the drop-down list Loads.
State of the radio-controlled socket after operation of the load or if the connection is
interrupted
Depending on the load type, the radio-controlled socket is either switched on or switched off
after load operation.
• Load is program-controlled: switched on
• Load is not program-controlled: switched off
The radio-controlled socket also switches to the respective state if the connection between the
SunnyHomeManager and the radio-controlled socket is interrupted for more than 15 minutes. In
this case you will need to reset the radio-controlled socket to the operating mode Automatic (see
Section9.4, page90) so that the SunnyHomeManager can continue to control the radio-
controlled socket.
9.2.5 Entering the Device Name
Using the device name, you can identify the SMAradio-controlled socket in the
SunnyHomeManager system.
9 Load Control
SMA Solar Technology AG
User ManualHoMan_Portal-BA-en-2076