Parameter List Overview SMA Solar Technology AG
178 SI2012_2224-TEN082311 Technical Description
250# Set System
For a detailed description of the "260# Set Password" menu see section 10.3.2 "Setting the
Installer Password" (Page 102).
17.3 Diagnosis
310# Diag Inverter
Menu
nr.
Parame
ter.Nr.
Parameter Name Range/Unit Default
value
Description
250 01 AutoStr
(Stby)
0 autostart (0=autostart deactivated)
250 02 Dt yyyymmdd Date
250 03 Tm hhmmss Time
250 06 ComBaud 1200
4800
9600
19200
38400
57600
115000
1200 baud rate interface
250 09 ComAdr interface address
250 23 BatVtgOut Auto
Off
On
Off Switching on and off of the battery
voltage output
250 26 SearchModTm sec 0 Searchmode timer
Menu
Nr.
Para-
meter
Nr.
Parameter Name Range/Unit Description
311# Diag Total
311 01 EgyCntIn kWh energy absorbed
311 02 E gyCnt Out kWh energy f ed
311 03 EgyCntTm h energy metering run time
312# Diag Device
312 02 F wVer BFR fi rmware versio n
312 03 SN Serial number
312 04 OnTmh h operating hours
312 06 OpStt Operating
Warning
Failure
operating mode (device)