SMA Solar Technology AG Sunny Island Electrical Connection
Technical Description SI2012_2224-TEN082311 51
7.4 Sunny Remote Control 1
The Sunny Remote Control 1 is connected to the
"Display" terminal in the Sunny Island.
Connection in a 3-Phase System
In a 3-phase system, always connect the master to phase L1, slave 1 to phase L2
and slave 2 to phase L3. This circuitry results in a right rotating field.
The system does not monitor additional fuses. Check any additional fuses regularly!
NOTICE!
The components in the Sunny Island (e.g., communications interface) can be
damaged by an electrostatic discharge!
When working on the Sunny Island and when handling the components observe all
ESD safety regulations.
Eliminate static charge by touching the grounded metal casing.
Only then should you begin any work.