EasyManuals Logo

SMC Networks VQC1000 Series Operation Manual

Default Icon
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
- 8 -
No.VQC1000V-OMM0002-B
VQC1000/2000 Series
Precautions for 5 Port Solenoid Valve
Be sure to read before handling.
3. Low-frequency operation
Valves should be operated at least once every 30 days to
prevent malfunction. (Use caution regarding the air supply.)
4. Manual override
When the manual override is operated, connected equipment
will be actuated.
Operate after safety is confirmed.
5. If the volume of air leakage increases or the
valve does not operate normally, do not use the
valve.
Perform periodic maintenance on the valve to
confirm the operating condition and check for
any air leakage.
1. Drain flushing
Remove drainage from the air filters regularly.
2. Lubrication
In the case of rubber seals, once lubrication has been started, it
must be continued.
Use class 1 turbine oil (with no additives), VG32. If other lubricant
oil is used, it may cause a malfunction. Please contact SMC for
information on the suggested class 2 turbine oil (with additives),
VG32.
3. Manual override operation
When switching a double solenoid valve via the manual override
operation, instantaneous operation may cause the malfunction of
the cylinder. It is recommended that the manual override be held
until the cylinder reaches the stroke end position.
Caution

Other manuals for SMC Networks VQC1000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks VQC1000 Series and is the answer not in the manual?

SMC Networks VQC1000 Series Specifications

General IconGeneral
BrandSMC Networks
ModelVQC1000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals