33
Warning
Manual Override
Caution
Solenoid Valve Removal and Mounting VQC1000/2000
Caution
Valve Mounting VQC4000
Proper tightening torque (N⋅m)
0.8 to 1.2
Locking type (manual) <Optional>
Non-locking push type (tool required)
Locking type (manual)
<Optional>
PUSH
TURN
LOCK
Push down the manual
override button with a small
screwdriver, etc., until it
stops.
The manual override will
return when released.
Push down the manual
override button with a small
screwdriver until it stops.
The manual override will
return when released.
Push down the manual
override button with a small
flat head screwdriver until it
stops, and turn it clockwise
90° to lock it. Turn it counter-
clockwise to release it.
Push down the manual
override button with a small
flat head screwdriver until it
stops, and turn it clockwise
90° to lock it. Turn it counter-
clockwise to release it.
Push down the manual
override button with a small
flat head screwdriver or with
your finger until it stops, and
turn it clockwise 90° to lock
it. Turn it counterclockwise
to release it.
VQC4000
VQC1000/2000
Removal steps
Mounting steps
Bore ø4.2
Bore ø3.2
Bore ø3.2
Bore ø4.2
11mm
VQC1000 VQC2000
VQC1000 VQC2000
VQC1000 VQC2000
Mounting screw (M3)
Bore ø5
Bore ø5
10mm
Series VQC
Specific Product Precautions 1
Be sure to read before handling.
Refer to pages 29 through 32 for safety instructions and common precautions.
Since connected equipment will operate when the
manual override is activated, confirm that conditions
are safe prior to activation.
The non-locking push type (tool required) is
standard, and the slotted locking type (tool required)
is optional.
Slotted locking type (tool required) <Optional>
Non-locking push type (tool required)
After confirming that the gasket is installed
correctly, securely tighten the mounting screws
according to the tightening torque shown
below.
1. Loosen the clamp screws until they turn freely. (The screws do
not come out.)
2. Remove the solenoid valve from clamp B by lifting the coil side
of the valve while pushing on the screw top.
If pushing down on the screw is difficult, you can alternately
press down on the valve gently in the area near the manual
override.
1. Push the clamp screws. Clamp A opens. Now insert the end
plate hook of the valve into clamp B from an angle.
2. Push the valve down into place. (When you release the screws,
the valve will be locked into clamp A.)
3. Tighten the clamp screws with a tightening torque of 0.25 to
0.35N⋅m for VQC1000 and 0.5 to 0.7N⋅m for VQC2000.
Do not let foreign matter stick on the seal side of the gasket and
solenoid, as this will cause air leakage.
Caution